The CAPILLARYS 3 TERA MC configuration allows the combination of one to three CAPILLARYS 3 TERA instruments to a Sebia loader, with a loading capacity of 528 samples in one row.
This high volume workcell provides 3 hours autonomy on HbA1c, and Hemoglobin testing, and more than 2 hours on Proteins, processing up to 528 samples in one go.
The system can be fed continuously with additional racks, and the reagent management system allows ad-hoc reagent addition at any time, without interruption.
The system allows on-the-fly rerouting of each loading lane. The user can also directly insert racks on one specific instrument (STAT).
Load and unload the sample racks at the same point.
Sample types: whole blood, urine, serum
With up to 36 capillaries, the high volume workcell CAPILLARYS 3 TERA MC can respond to the highest volume with a low hands-on-time. The loader can receive 66 racks in one go (528 samples).
Values for MC3 Throughput (tests/hour)* System autonomy (minutes)
PROTEIN(E) 6 (serum) 243 130
PROTEIN(E) 6 (urine) 238 133
IMMUNOTYPING (serum or urine) 27 1173
Hb A1c 176 180
HEMOGLOBIN(E) 176 180
CDT 179 177
* Using Software version 9.30
High throughput Serum Protein Electrophoresis, with high resolution results.
High throughput Urine Protein Electrophoresis, with high resolution results.
Fully automated monoclonal proteins identification by Capillarys electrophoresis.
The high-resolution method for hemoglobin disorders screening.
The most reliable chronic alcohol abuse marker.
Interview between Sebia and M. Jean Deenmamode, CDT IFCC Working Group Chair
Understand in 2 minutes how capillary electrophoresis works, and why it gives such high and clear resolution in lab testing.
Understand your needs and constraints to provide you with the most suitable and integrated solution.
Improve your lab performance by optimizing your Sebia solutions.
IFCC Euromedlab 2021
Sebia booth: #121
Sebia Workshop: EduW22
Educational Webinar with Prof. Alessandro Gozzetti, MD, PhD
Educational Webinar with Dr. Julien GUILLEMAUD
IFCC Worldlab 2022
Sebia booth: #72
Sebia Workshop: EduW25
With this short video report, become aware of all the benefits of partnering with Sebia and integrate your capillary electrophoresis into the lab track automation.
Educational Webinar with David G. Grenache, PhD, D(ABCC)
Chief Scientific Officer, TriCore Reference Laboratories
Educational Webinar with Dr. Mark Zaydman from Washington University School of Medicine in St. Louis, MO
Educational Webinar Pr Simone Scarlata
Educational Webinar with Jason EYRE
Educational Webinar with Dr. Jack Maggiore from Loyola University Medical Center in Chicago, IL
Educational Webinar with Dr. Jack Maggiore from Loyola University Medical Center in Chicago, IL
Educational Webinar with Prof. Giovanni PALLADINI, PhD
IFCC Euromedlab /WorldLab 2023
Sebia booth: #21
Sebia Workshop: EduW15
Educational Webinar with Dr. Ilaria Ferrarotti
European Myeloma Network Meeting – EMN 2024
Sebia booth: #9
IFCC CDT-Working Group standardized the CDT measurement.
Article from Jean Deenmamode, IFCC CDT working group chair in CLI magazine.
The EurA1c trial, organized yearly, investigates the performance of HbA1c assays across countries and manufacturers.
This article assesses the performances of the different manufacturers and technologies (HPLC and CE) for Hb A2 measurement using both International Reference Reagent for HbA2 (WHO IRR 89/666) and analysis of three whole blood specimens over a range of HbA2, distributed to 56 laboratories located in 14 different countries.
This section contains information intended for wide distribution and may therefore contain product details or information that is not available or valid in your country.
Please contact your local Sebia representative. Information intended for healthcare professionals.
Carefully read the instructions in the reagent package inserts and instrument manuals.